Short answer: Diethyl Ether (CAS 60-29-7) is not an EPCRA §302 extremely hazardous substance, but it is listed under CERCLA and CAA 112(r). Its CAA 112(r) threshold quantity is 10,000 lb in a process. The lowest of its federal thresholds is 100 lb (CERCLA reportable quantity).
Federal thresholds, lowest first
| Threshold | Diethyl Ether | Measured as | What it triggers | Citation |
|---|---|---|---|---|
| CERCLA reportable quantity (RQ) | 100 lb | Released within 24 hours | Release notification to the National Response Center | 40 CFR 302.4 |
| Tier II (EPCRA §312) reporting threshold | 10,000 lb | On site at any one time | Listing on the Tier II report, if it is a hazardous chemical that needs an SDS under OSHA HazCom | 40 CFR 370.10(a)(2) |
| CAA 112(r) threshold quantity | 10,000 lb | In a single process | Risk Management Program and plan | 40 CFR 68.130 |
40 CFR 302.4 also lists Diethyl Ether with RCRA hazardous waste number U117, which applies when it is discarded as a commercial chemical product.
Other names
Diethyl Ether also appears as: ethane, 1,1'-oxybis-; ethyl ether; ether; ethoxyethane; ethyl oxide; pronarcol; diethyl oxide; aether; anesthetic ether; anaesthetic ether; solvent ether.
Check a quantity
Use the Tier II threshold checker. Chemsana does this for every chemical on site at once: it totals Diethyl Ether across every product by CAS number, checks it against each of these programs, and flags a purchase that would cross a threshold before it arrives. See intake decisions.
Sources
- EPA Consolidated List of Lists, EPA List of Lists, April 2025, loaded into Chemsana and synced November 7, 2026.
- 40 CFR Part 355, Appendix A (EHS list with TPQs and reportable quantities), eCFR.
- 40 CFR 370.10, thresholds for Tier II reporting, eCFR.
- 40 CFR 302.4, CERCLA hazardous substances and reportable quantities, eCFR.
- 40 CFR 68.130, CAA 112(r) regulated substances and threshold quantities, eCFR.
Generated from EPA data, not written by hand. It summarizes federal requirements for general information. States can set lower thresholds or extra requirements, and it is not legal advice. Confirm obligations with your SERC, LEPC, or a qualified EHS professional.