Short answer: Ethyl Nitrite (CAS 109-95-5) is not an EPCRA §302 extremely hazardous substance, but it is listed under CAA 112(r) and OSHA PSM. Its CAA 112(r) threshold quantity is 10,000 lb in a process. Its OSHA PSM threshold quantity is 5,000 lb. The lowest of its federal thresholds is 5,000 lb (OSHA PSM threshold quantity).
Federal thresholds, lowest first
| Threshold | Ethyl Nitrite | Measured as | What it triggers | Citation |
|---|---|---|---|---|
| OSHA PSM threshold quantity | 5,000 lb | In a process | Process safety management program | 29 CFR 1910.119 App. A |
| Tier II (EPCRA §312) reporting threshold | 10,000 lb | On site at any one time | Listing on the Tier II report, if it is a hazardous chemical that needs an SDS under OSHA HazCom | 40 CFR 370.10(a)(2) |
| CAA 112(r) threshold quantity | 10,000 lb | In a single process | Risk Management Program and plan | 40 CFR 68.130 |
Other names
Ethyl Nitrite also appears as: nitrous acid, ethyl ester; nitrosyl ethoxide; hyponitrous ether; nitrous ethyl ether; ethylester kyseliny dusite; nitrous ether; ethyl-nitrite-; nitrous acid ethyl ester.
Check a quantity
Use the Tier II threshold checker. Chemsana does this for every chemical on site at once: it totals Ethyl Nitrite across every product by CAS number, checks it against each of these programs, and flags a purchase that would cross a threshold before it arrives. See intake decisions.
Sources
- EPA Consolidated List of Lists, EPA List of Lists, April 2025, loaded into Chemsana and synced November 7, 2026.
- 40 CFR Part 355, Appendix A (EHS list with TPQs and reportable quantities), eCFR.
- 40 CFR 370.10, thresholds for Tier II reporting, eCFR.
- 40 CFR 68.130, CAA 112(r) regulated substances and threshold quantities, eCFR.
- 29 CFR 1910.119, Appendix A, OSHA PSM highly hazardous chemicals, eCFR.
Generated from EPA data, not written by hand. It summarizes federal requirements for general information. States can set lower thresholds or extra requirements, and it is not legal advice. Confirm obligations with your SERC, LEPC, or a qualified EHS professional.