Osmium Tetroxide: federal reporting thresholds

CAS 20816-12-0. Listed under CERCLA, OSHA PSM and TRI. Every federal threshold for Osmium Tetroxide, lowest first, each from the eCFR text with its citation.

Short answer: Osmium Tetroxide (CAS 20816-12-0) is not an EPCRA §302 extremely hazardous substance, but it is listed under CERCLA, OSHA PSM and TRI. Its OSHA PSM threshold quantity is 100 lb. The lowest of its federal thresholds is 100 lb (OSHA PSM threshold quantity).

Federal thresholds, lowest first

ThresholdOsmium TetroxideMeasured asWhat it triggersCitation
OSHA PSM threshold quantity100 lbIn a processProcess safety management program29 CFR 1910.119 App. A
CERCLA reportable quantity (RQ)1,000 lbReleased within 24 hoursRelease notification to the National Response Center40 CFR 302.4
Tier II (EPCRA §312) reporting threshold10,000 lbOn site at any one timeListing on the Tier II report, if it is a hazardous chemical that needs an SDS under OSHA HazCom40 CFR 370.10(a)(2)
TRI (EPCRA §313) reporting threshold25,000 lb per year manufactured or processed; 10,000 lb otherwise usedManufactured, processed, or otherwise used in a yearForm R or Form A, due July 1, for covered industries with 10 or more full-time employees. Default TRI thresholds40 CFR 372.25
Each threshold is measured differently, so the lowest number is not always the first one you reach. Count every pound of Osmium Tetroxide across the site, including its share of every mixture (how mixtures count). How the programs compare: thresholds compared.

40 CFR 302.4 also lists Osmium Tetroxide with RCRA hazardous waste number P087, which applies when it is discarded as a commercial chemical product.

Other names

Osmium Tetroxide also appears as: osmium tetraoxide; osmic acid; tetraoxoosmium; perosmic oxide; osmic acid anhydride; perosmic acid anhydride; acid, osmic.

Check a quantity

Use the Tier II threshold checker. Chemsana does this for every chemical on site at once: it totals Osmium Tetroxide across every product by CAS number, checks it against each of these programs, and flags a purchase that would cross a threshold before it arrives. See intake decisions.

Sources

  1. EPA Consolidated List of Lists, EPA List of Lists, April 2025, loaded into Chemsana and synced November 7, 2026.
  2. 40 CFR Part 355, Appendix A (EHS list with TPQs and reportable quantities), eCFR.
  3. 40 CFR 370.10, thresholds for Tier II reporting, eCFR.
  4. 40 CFR 302.4, CERCLA hazardous substances and reportable quantities, eCFR.
  5. 29 CFR 1910.119, Appendix A, OSHA PSM highly hazardous chemicals, eCFR.
  6. 40 CFR 372.65, TRI chemicals, with thresholds in 372.25 and 372.28, eCFR.

Generated from EPA data, not written by hand. It summarizes federal requirements for general information. States can set lower thresholds or extra requirements, and it is not legal advice. Confirm obligations with your SERC, LEPC, or a qualified EHS professional.