Propylene Oxide: federal reporting thresholds

CAS 75-56-9. Listed under EPCRA 302, EPCRA 304, CERCLA, CAA 112(r) and TRI. Every federal threshold for Propylene Oxide, lowest first, each from the eCFR text with its citation.

Short answer: Propylene Oxide (CAS 75-56-9) is an extremely hazardous substance (EHS) under EPCRA §302. Its threshold planning quantity is 10,000 lb. Its Tier II reporting threshold is 500 lb, and its EPCRA §304 reportable quantity is 100 lb. It is also listed under CERCLA, CAA 112(r) and TRI.

Federal thresholds, lowest first

ThresholdPropylene OxideMeasured asWhat it triggersCitation
EPCRA §304 reportable quantity (RQ)100 lbReleased within 24 hoursRelease notification to the SERC and LEPC40 CFR 355 App. A
CERCLA reportable quantity (RQ)100 lbReleased within 24 hoursRelease notification to the National Response Center40 CFR 302.4
Tier II (EPCRA §312) reporting threshold500 lbOn site at any one timeListing on the Tier II report, due March 140 CFR 370.10(a)(1)
EPCRA §302 threshold planning quantity (TPQ)10,000 lbOn site at any one timeEmergency planning notice to the SERC and LEPC within 60 days40 CFR 355 App. A
CAA 112(r) threshold quantity10,000 lbIn a single processRisk Management Program and plan40 CFR 68.130
TRI (EPCRA §313) reporting threshold25,000 lb per year manufactured or processed; 10,000 lb otherwise usedManufactured, processed, or otherwise used in a yearForm R or Form A, due July 1, for covered industries with 10 or more full-time employees. Default TRI thresholds40 CFR 372.25
Each threshold is measured differently, so the lowest number is not always the first one you reach. Count every pound of Propylene Oxide across the site, including its share of every mixture (how mixtures count). How the programs compare: thresholds compared.

The thresholds in gallons

At a specific gravity of 0.859, a US gallon of Propylene Oxide weighs 7.16 lb (0.859 × 8.34). Basis: the pure liquid at 0 °C (NOAA CAMEO Chemicals 3.1.0 rev 1, citing EPA, 1998).

ThresholdPoundsGallons of the pure liquid
EPCRA §304 reportable quantity (RQ)
CERCLA reportable quantity (RQ)
10013.9
Tier II (EPCRA §312) reporting threshold50069.7
EPCRA §302 threshold planning quantity (TPQ)
CAA 112(r) threshold quantity
TRI threshold, otherwise used
10,0001,395
TRI threshold, manufactured or processed25,0003,489
Gallons are rounded down. A solution or mixture holds less Propylene Oxide per gallon. Use the specific gravity and concentration from your SDS, as shown in the gallons to pounds guide, or try the calculator.

Other names

Propylene Oxide also appears as: oxirane, methyl-; 1,2-epoxypropane; methyloxirane; propene oxide; epoxypropane; propyleneoxide; 1,2-propylene oxide; propylene epoxide; 2,3-epoxypropane; methyloxacyclopropane.

Check a quantity

Enter what you hold in the TPQ lookup or the Tier II threshold checker or the gallons to pounds calculator. Chemsana does this for every chemical on site at once: it totals Propylene Oxide across every product by CAS number, checks it against each of these programs, and flags a purchase that would cross a threshold before it arrives. See intake decisions.

Sources

  1. EPA Consolidated List of Lists, EPA List of Lists, April 2025, loaded into Chemsana and synced November 7, 2026.
  2. 40 CFR Part 355, Appendix A (EHS list with TPQs and reportable quantities), eCFR.
  3. 40 CFR 370.10, thresholds for Tier II reporting, eCFR.
  4. 40 CFR 302.4, CERCLA hazardous substances and reportable quantities, eCFR.
  5. 40 CFR 68.130, CAA 112(r) regulated substances and threshold quantities, eCFR.
  6. 40 CFR 372.65, TRI chemicals, with thresholds in 372.25 and 372.28, eCFR.

Generated from EPA data, not written by hand. It summarizes federal requirements for general information. States can set lower thresholds or extra requirements, and it is not legal advice. Confirm obligations with your SERC, LEPC, or a qualified EHS professional.