Short answer: Thionyl Chloride (CAS 7719-09-7) is not an EPCRA §302 extremely hazardous substance, but it is listed under OSHA PSM. Its OSHA PSM threshold quantity is 250 lb. The lowest of its federal thresholds is 250 lb (OSHA PSM threshold quantity).
Federal thresholds, lowest first
| Threshold | Thionyl Chloride | Measured as | What it triggers | Citation |
|---|---|---|---|---|
| OSHA PSM threshold quantity | 250 lb | In a process | Process safety management program | 29 CFR 1910.119 App. A |
| Tier II (EPCRA §312) reporting threshold | 10,000 lb | On site at any one time | Listing on the Tier II report, if it is a hazardous chemical that needs an SDS under OSHA HazCom | 40 CFR 370.10(a)(2) |
Other names
Thionyl Chloride also appears as: thionyl dichloride; sulfinyl chloride; sulfurous dichloride; sulfurous oxychloride; sulfinyl dichloride; sulfur oxychloride; sulfur chloride oxide.
Check a quantity
Use the Tier II threshold checker. Chemsana does this for every chemical on site at once: it totals Thionyl Chloride across every product by CAS number, checks it against each of these programs, and flags a purchase that would cross a threshold before it arrives. See intake decisions.
Sources
- EPA Consolidated List of Lists, EPA List of Lists, April 2025, loaded into Chemsana and synced November 7, 2026.
- 40 CFR Part 355, Appendix A (EHS list with TPQs and reportable quantities), eCFR.
- 40 CFR 370.10, thresholds for Tier II reporting, eCFR.
- 29 CFR 1910.119, Appendix A, OSHA PSM highly hazardous chemicals, eCFR.
Generated from EPA data, not written by hand. It summarizes federal requirements for general information. States can set lower thresholds or extra requirements, and it is not legal advice. Confirm obligations with your SERC, LEPC, or a qualified EHS professional.