Short answer: Ammonia (CAS 7664-41-7) is an extremely hazardous substance (EHS) under EPCRA §302. Its threshold planning quantity is 500 lb. Its Tier II reporting threshold is 500 lb, and its EPCRA §304 reportable quantity is 100 lb. It is also listed under CERCLA, CAA 112(r), OSHA PSM and TRI.
Federal thresholds, lowest first
| Threshold | Ammonia | Measured as | What it triggers | Citation |
|---|---|---|---|---|
| EPCRA §304 reportable quantity (RQ) | 100 lb | Released within 24 hours | Release notification to the SERC and LEPC | 40 CFR 355 App. A |
| CERCLA reportable quantity (RQ) | 100 lb | Released within 24 hours | Release notification to the National Response Center | 40 CFR 302.4 |
| EPCRA §302 threshold planning quantity (TPQ) | 500 lb | On site at any one time | Emergency planning notice to the SERC and LEPC within 60 days | 40 CFR 355 App. A |
| Tier II (EPCRA §312) reporting threshold | 500 lb | On site at any one time | Listing on the Tier II report, due March 1 | 40 CFR 370.10(a)(1) |
| CAA 112(r) threshold quantity (Ammonia (anhydrous)) | 10,000 lb | In a single process | Risk Management Program and plan | 40 CFR 68.130 |
| OSHA PSM threshold quantity (Ammonia, Anhydrous) | 10,000 lb | In a process | Process safety management program | 29 CFR 1910.119 App. A |
| TRI (EPCRA §313) reporting threshold | 25,000 lb per year manufactured or processed; 10,000 lb otherwise used | Manufactured, processed, or otherwise used in a year | Form R or Form A, due July 1, for covered industries with 10 or more full-time employees. Default TRI thresholds | 40 CFR 372.25 |
| OSHA PSM threshold quantity (Ammonia solutions (>44% ammonia by weight)) | 15,000 lb | In a process | Process safety management program | 29 CFR 1910.119 App. A |
| CAA 112(r) threshold quantity (Ammonia (conc 20% or greater)) | 20,000 lb | In a single process | Risk Management Program and plan | 40 CFR 68.130 |
Other names
Ammonia also appears as: ammonia, anhydrous; azane; ammonia gas; nitro-sil; ammonia anhydrous; anhydrous ammonia; ammoniak; liquid ammonia; am-fol; ammoniac.
Check a quantity
Enter what you hold in the TPQ lookup or the Tier II threshold checker. Chemsana does this for every chemical on site at once: it totals Ammonia across every product by CAS number, checks it against each of these programs, and flags a purchase that would cross a threshold before it arrives. See intake decisions.
Sources
- EPA Consolidated List of Lists, EPA List of Lists, April 2025, loaded into Chemsana and synced November 7, 2026.
- 40 CFR Part 355, Appendix A (EHS list with TPQs and reportable quantities), eCFR.
- 40 CFR 370.10, thresholds for Tier II reporting, eCFR.
- 40 CFR 302.4, CERCLA hazardous substances and reportable quantities, eCFR.
- 40 CFR 68.130, CAA 112(r) regulated substances and threshold quantities, eCFR.
- 29 CFR 1910.119, Appendix A, OSHA PSM highly hazardous chemicals, eCFR.
- 40 CFR 372.65, TRI chemicals, with thresholds in 372.25 and 372.28, eCFR.